20% OFF shipping at oberhaunstadt.com on orders over $79 + up to 10% OFF products
oberhaunstadt.com
home > Endress+Hauser 6BAB Proline t-mass B150 thermal mass flowmeter > Endress+Hauser 6BAB Proline t-mass B150 thermal mass flowmeter
download picture
Endress+Hauser 6BAB Proline t-mass B150 thermal mass flowmeterOverview Endress+Hauser Proline t mass B150 thermal mass flowmeter is a flowmeter for cost effective measurement and easy monitoring of utility gases. Specs at a glance * Max. measurement error 3 % o. r. 4 % o. r. 5 % o. f. s. (depending on chosen option of ordering feature "Calibration flow") * Measuring range 20 to 720 000 kg h (45 to 1 587 600 lb h) 20 to 1 080 000 kg h (45 to 2 381 400 lb h) (for air, depending on chosen option of ordering feature
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Overview

Endress+Hauser Proline t-mass B150 thermal mass flowmeter is a flowmeter for cost-effective measurement and easy monitoring of utility gases.

Specs at a glance

* Max. measurement error
3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")
* Measuring range
20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
* Medium temperature range
–40 to +100 °C (–40 to +212 °F)
* Max. process pressure
20 bar g (290 psi g)
* Wetted materials
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G 
 

Field of application

The t-mass B 150 insertion version is suitable for large pipelines or rectangular ventilation ducts. It is designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. Its 4-wire technology is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
* Measuring principle is characterized by a high operable flow range and direct mass flow measurement
* Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.


Device properties
* Insertion version for nominal diameter DN 80 to 1500 (3 to 60")
* Installation and removal of sensor without process interruption
* Easy installation
* Device in compact version with DC 24 V power supply
* 4-20 mA HART, pulse/frequency/switch output
* Compact and robust transmitter

Benefits

 * Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts
* Optimal process monitoring – easy measurement even at low pressures and flow velocities
* Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free
* Reliable flow trending – multivariable measurement
* Fast and efficient commissioning – guided operating menus
* High plant availability – self-diagnostics and error monitoring
* Automatic recovery of data for servicing

Specification

Measuring Principle Thermal
Product Headline The flowmeter for cost-effective measurement and easy monitoring of utility gases. 
Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.
Sensor Features Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effective measurement – easy 
installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement. 
Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption. 
Easy installation.
Transmitter Features Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. 
Automatic recovery of data for servicing. 
Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter.
Nominal Diameter Range DN 80 to 1500 (3 to 60")
Wetted Materials Transducer: 1.4404 (316L) 
Insertion tube: 1.4404 (316L); 1.4435 (316L) 
Connection: 
Compression fitting: 1.4404 (316L) 
Sealing ring: EPDM; HNBR; 1.4401 (316) 
Clamping ring: PEEK 450G
Measured Variables Mass flow, temperature, corrected volume flow, FAD volume flow
Max. Measurement Error 3 % o.r. 
4 % o.r. 
5 % o.f.s. 
(depending on chosen option of ordering feature "Calibration flow")
Measuring Range 20 to 720 000 kg/h (45 to 1 587 600 lb/h) 
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h) 
(for air, depending on chosen option of ordering feature "Calibration flow")
Max. Process Pressure 20 bar g (290 psi g)
Medium Temperature Range –40 to +100 °C (–40 to +212 °F)
Ambient Temperature Range –40 to +60 °C (–40 to +140 °F)
Transmitter Housing Material AlSi10Mg, coated
Degree Of Protection IP66/67, type 4X enclosure
Display/Operation 4‐line display with push Buttons 
Configuration via local display and operating tools possible
Outputs 4‐20 mA HART (active) 
Pulse/frequency/switch output (passive)
Inputs Status input
Digital Communication HART
Power Supply DC 18 to 30 V
Hazardous Area Approvals ATEX, IECEx, cCSAus
Metrological Approvals And Certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure Approvals And Certificates CRN

 

Endress+Hauser 6BAB Proline t-mass B150 thermal mass flowmeter

Item no : 18779727781
sold recently : Login >>
US$ 1350.00
Pay in 4 interest-free payments of $337.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 1350.00

1-11

US$ 1215.00

12-35

US$ 945.00

36-59

US$ 810.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]