20% OFF shipping at oberhaunstadt.com on orders over $79 + up to 10% OFF products
oberhaunstadt.com
home > 2000 kW (2 mW) MTU Diesel Generator (480/277V Three Phase 60Hz) > 2000 kW (2 mW) MTU Diesel Generator (480/277V Three Phase 60Hz)
download picture
2000 kW (2 mW) MTU Diesel Generator (480/277V Three Phase 60Hz)*All Pictures shown are for illustration purposes only. Actual product may vary due to enhancement* 8 10 Week Lead Time 1 year 1000 hours Warranty with Free parts and service guidance! Master industrial generator sets are fully integrated power generation systems that provide optimum performance, dependability, and versatility for standby power, prime power and continuous power applications. Powered by MTU (Rolls Royce) Engine, Stamford Alternator,
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols
*All Pictures shown are for illustration purposes only. Actual product may vary due to enhancement*

8 - 10 Week Lead Time

1-year/1000 hours Warranty with Free parts and service guidance!

Master industrial generator sets are fully integrated power generation systems that provide optimum performance, dependability, and versatility for standby power, prime power and continuous power applications. 

Powered by MTU (Rolls Royce) Engine, Stamford Alternator, and Deepsea Control Panel

Included Features 

  • Technologically advanced Remote Wifi Controller 
  • Next-Generation Brushless Stamford CSA Approved Alternator 
  • Inbuilt Webasto Style Coolant Heater to prevent cold starts and increase the engine's longevity 
  • Silent Soundproof Weather Protection Canopy/Enclosure 
  • Standard 8 Hour Dual Wall Base Fuel Tank 
  • Electronic Speed Governor

Prime power 

This rating is for continuous electrical power supply (at variable load). There is no limit on the annual hours of operation, and 10% overload power can be supplied for 1 hour in 12. 

Standby power 

This rating is for the supply of continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted. 

Features 

  • Every generator set is subjected to a comprehensive test program which includes 50% load, 75% load, 100% load, 110% load and the checking and proving of all control and safety shut-down functions
  • 24V DC start motor
  • Equipped 24V high-performance maintenance-free lead-acid starting batteries
  • Equipped with industrial silencer and flexible exhaust hose
  • Designed to Comply with ISO8528/GB2820 

General Data 

Model Number 

MPM-2000-3480-60

Power 

2000 kW (2 mW) / 2500 kVA

Voltage

480/277V 

Phase

3 (Three Phase) 

Power Factor 

0.8

Engine Manufacturer

MTU (Rolls Royce)

Alternator Manufacturer

Stamford 

Control Panel Manufacturer

Deepsea

MTU Engine Technical Data

Model (Qty. 2)

16V 2000 G85

Manufacturer 

MTU (Rolls Royce)

Number of Cylinders 

16 Cylinders

Cycle 

4 Stroke 

Aspiration 

Turbocharged and aftercooled

Bore x Stroke (mm x mm) 

130 x 150 

Displacement 

31.84 L 

Compression Ratio 

16:1

Prime Power/Speed 

1010 kW/1800rpm 

Standby Power/Speed 

1114 kW/1800rpm 

Speed Governor 

ECM 

Cooling System 

Forced Liquid Cooling Cycle 

Steady Speed Drop 

≤1% 

Total Coolant Capacity 

110 L 

Fuel Consumption at 100% Load 

241 L/h 

Starter Motor 

DC24V 

Alternator 

DC24V 

Stamford Alternator Technical Data 

Alternator Model 
(Qty. 2)

HCI634J CSA Approved 

Power 

1000 kW 

Frequency/Speed 

60Hz/1800rpm 

Exciter Type 

Single Bearing, Brushless, Self-excited 

Power Factor 

0.8

Voltage Adjust Range 

≥5% 

Voltage Regulation NL-FL 

≤+1% 

Insulation Grade 

Protection Grade 

IP23 

Phase 

3

Deepsea Control Panel Technical Data 

Model
DSE

The control module gives digital readouts of (Including but not limited to):
  • Generator voltage
  • Output frequency
  • Engine speed
  • Battery voltage
  • Engine hours run

The control module has indicators for the following failure information (Including but not limited to): 
  • Overspeed/underspeed
  • Emergency stop
  • Low oil pressure
  • High water temperature
  • Failure to start 
  • Battery charger failure

Automatic shutdown occurs under (Including but not limited to):
  • Low engine oil pressure
  • High engine water temperature
  • Overspeed/underspeed
  • Failure to start after three attempts

Options/Add-Ons Available 

For more details, call or text: +1 (647) 363-5872

2000 kW (2 mW) MTU Diesel Generator (480/277V Three Phase 60Hz)

Item no : 90650199596
sold recently : Login >>
US$ 25000.00
Pay in 4 interest-free payments of $6250.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 25000.00

1-11

US$ 22500.00

12-35

US$ 17500.00

36-59

US$ 15000.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches